Dataquest ART
- Cable Access Adapter Pin Assignments Read More >>
-
C12V Analog to Frequency Converter Manual
Please note, the C12V is discontinued. Discontinued Product List
Read More >> -
C11V Analog to Digital Converter User Manual
Please note, the C11V is discontinued. Discontinued Product List
Read More >> -
DL10 Analog Output Manual
Please note, the DL10 is discontinued. Discontinued Product List
Read More >> -
Option R08 Analog ECG Output Adapter User Manual
Please note, the Option R08 is discontinued. Discontinued Product List
Read More >> -
ART Manual: Configuring and Using the Distributed Receiver Array (DRA)
This example demonstrates the DRA setting at 4. This means that there will be 4 receivers per cage. The DRA function automatically groups adjacent jacks. The Configuration program automatically sel...
Read More >> -
How to extract Heart Rate Parameter from ECG waveforms in Dataquest ART
If the Heart Rate Parameter was not selected in the Source Settings window of the Dataquest ART Acquisition program prior the acquisition, the Heart Rate parameter series can be manually extracted ...
Read More >> -
Filtering EMG Data using Dataquest ART
The bottom most signal is the EMG signal The next one up is the EMG filter with a High Pass filter at 50-75 Hz. To do this: Select the EMG signal Right-click and select Filter Actions - High Pas...
Read More >> -
PhysioTel and PhysioTel HD Configuration using Dataquest ART/OpenART Interface
The video below demonstrating the software configuration of PhysioTel and PhysioTel HD implants using the Dataquest ART interface. The concepts in the demonstration are also applicable to implant c...
Read More >> -
How to change the parameters averaging interval in Dataquest ART
In Dataquest ART, the Segment Duration (which translates into the 'logging interval' in Ponemah) is normally set before collecting the data: However, if the data was collected with a 10-seco...
Read More >> -
BioDAQ system setup with DSI telemetry
The BioDAQ system from Research Diets is a valuable tool for monitoring food and liquid intake as well as automating access to or restriction from food and liquid. Integration of the DSI telemetry ...
Read More >> -
Dataquest ART Tau Calculation
The formula for Tau is where M is the slope of a linear fit of the natural log (ln) of pressure points from min dP/dt to a terminus. The terminus shall be set to 66% of the total pressure drop in ...
Read More >> -
How to repair Dataquest ART files using the newlook utility
Dataquest ART files may become corrupt if the software is not able to gracefully close out the files being written to. This usually happens if there is a power outage or some other complication tha...
Read More >> -
How to reset Dataquest ART password requirements
For Dataquest ART Versions 3.1 and Older Delete the file password.bin from the Dataquest ART run-time folder (typically c:\Dataquest ART). For Dataquest ART Versions 4.0 and Newer Delete the file ...
Read More >> -
How to reduce the parameter data output using Dataquest ART analysis
Background: This article will provide the necessary steps to perform Dataquest ART's moving average function to reduce the number of parameter values output from the system to user defined interval...
Read More >>