Implants shift in Ponemah 5.20 if implants are removed from MX2 or CLC interfaces
Symptoms
Should a user delete an Implant that is not the last Implant in the Hardware | Select Implants list when using the MX2/CLC, the Implant will be shifted in the Channel Input Setup.
This causes the attributes and graphs in the protocol file to no longer be correct for the Implant that followed the deleted Implant .
If a new Implant is added to replace the deleted Implant, the newly added Implant may not use the same index as the old Implant, causing the protocol file to be incorrect.
If using Study this will break the updating of Study data since each Implant table relies on the channels to be consistent for the Implant that are still in the Study.
The Select Implants dialog does not allow the user to re-order the Implant since it sorts the list alphabetically.
Workaround
There currently is not a workaround for this issue.