Ponemah v5x Acquisition & Review
-
Diaphragmatic Electromyogram Acquisition & Analysis in Ponemah v5.x
The Diaphragmatic Electromyogram (dEMG) Analysis Module analyzes electrocardiogram signals obtained from the diaphragm to calculate respiratory derived parameters. The analysis calculates derived p...
Read More >> -
SEND Setup
SEND SETUP FROM PPP3 SETUP In order to create SEND output, users must have enabled Data Reduction, selected derived parameters in the Channel Input Setup menu that correspond to output designated b...
Read More >> -
Configuring Study Workups when using Ponemah SEND module
Background SEND, Standard for Exchange of Nonclinical Data, is a standardized method to exchange data between organizations and for data submission to the FDA or other regulatory bodies for non-cli...
Read More >> -
Data Synchronization Card Installation Instructions for Ponemah 5.20-SP9+ and Ponemah v5.3x
The Measurement Computing PCI Quad04 board provides time synchronization data acquisition between DSI’s different acquisition hardware. Provides synchronization between DSI’s: PhysioTel or PhysioT...
Read More >> -
How to uninstall Ponemah 5.20 P3Plus and P3PlusTest SQL databases
The following outlines the process to uninstall the P3Plus and P3PlusTest SQL databases that are installed with the Ponemah v5.20 application from a Windows 7 operating system: Select the Windows...
Read More >> -
Appending Marks Section Name to Study Generated Files using Ponemah v5.20-SP8
Background The Study option is a software module that provides a structured handling of all data generated for an experiment. It allows the user to create the entire experiment prior to any collec...
Read More >> -
How to edit the Ponemah v5.x Experimental Protocol Header Information
Background The Experimental Protocol Header allows additional study information to be entered into the protocol and logged in the Excel (or Access) generated files. This information is saved withi...
Read More >> -
Combining .RAW files using Ponemah v5.20
Background The Combine Raw Files feature is used to concatenate two or more RAW files after a catastrophic failure. For example, if collecting data for 24 hours and a power failure occurs at hour ...
Read More >> -
Ponemah SEND Remote Server Synchronization Setup
Compatibility The following instructions require the Ponemah SEND v3.1 module and apply to Ponemah v5.31 and greater. Please note, the Ponemah SEND 3.1 module is not compatible with Ponemah v6.x. ...
Read More >> -
Configuring a PhysioTel Digital Implant for BPR Analysis in Ponemah v5.20
The following steps explain how to enable a soft channel for a PhysioTelTM Digital implant in order for it to be used with Ponemah’s BPR analysis module to determine respiration from blood pressure...
Read More >> -
How to import Experimental Protocol Header settings from a file
Background The Experimental Protocol Header allows additional study information to be entered into the protocol and logged in the Excel (or Access) generated files. Information from these fields c...
Read More >> -
Configuring Network Study
The attached power point leads a user through the needed steps to configure Study in a Network environment. This includes the configuration of SQL Server on the local workstation.
Read More >> -
Configuring Ponemah v5.20 SP7+ with MX2 interface for optimal file handling in NeuroScore
If Ponemah v5.20 is used to record data AND video for analysis in NeuroScore, it is critical that these steps are followed to ensure proper handling of the files. This is intended to be a suppleme...
Read More >> -
Creating Stagger Days within Ponemah v5.20 Study Protocol Option
Background Stagger Days were designed to accommodate the large number of subjects that could be used in the traditional multi-lead ECG collections (Tox study). In these Tox studies, it was not unco...
Read More >> -
How to assign Group Names as spreadsheet Labels in Ponemah v5.20
Background Information typed into the Name field in the Groups tab (shown below) would propagate to the Data Reduction and Experimental Protocol Header menus to assist with animal and channel ident...
Read More >> -
PhysioTel Digital Implant Order using Ponemah v5.x
Background When using PhysioTel Digital Implants with Ponemah v5.10 through v5.20 Service Pack 8, the order in which the Communication Link Controller (CLC) and implants are configured will impact ...
Read More >> -
Ponemah Data Security Utility
Overview The Data Security Settings Export Utility allows a user to quickly copy all Data Security settings (User List, Access Levels, and Security Preferences) defined from one workstation to anot...
Read More >> -
Ponemah v5.x Study Automation Scripts
Background The Study option is used to configure an entire study prior to any collection and handle all files generated by acquisitions and post processing sessions. Since the configuration of som...
Read More >> -
Resetting Ponemah Access Card User Pins
To prevent un-authorized Users from gaining access to the Ponemah system, an Access Card will be disabled upon five consecutive invalid attempts to enter a PIN (this security control is not optiona...
Read More >> -
Understanding Ponemah v5.x Study Protocol Option Synchronization and Backup Options
Background The Study option is used to configure an entire study prior to any collection and handle all files generated by acquisitions and post processing sessions. Many study designs require the...
Read More >> -
Video Tutorial - How to Configure PhysioTel Digital Implants using the legacy Configuration Wizard
This video details the process to configure PhysioTel Digital implants using the Configuration Wizard. This is the process for the following software versions. Ponemah v5.10 (all Service Packs [SP...
Read More >>